Hydrogeology

GPR for hydrogeological studies

The geological and geomorphological structures that can be detected through the GPR are::

Identification of underground flows and reservoirs of water

Hydrogeological characterization

Identification of areas of greater reservoir capacity

Characterization of the structural environment.

Identification of buried river valleys.

The buried river valleys are the most productive source of drinking water. These underground valleys can be found at different depths of the surface under different sediments. The water can be located in permeable rocks such as sands, gravels or limestones, and surrounded by impermeable rocks (what are called 'confined aquifer').

The GPR allows the detection of faults, which are usually a source of water. Often, the river valleys fit into tectonic faults. This can be seen in the figure below: there is a clear connection between the fault and the river valley. We can identify structural and paleogeographical regularities from certain types of geoelectric sections.

How the ground water can be detected by GPR?

Permittivity of water
Typical values for permittivity ε are:
  • water = 80,
  • saturated sand = 20 – 30,
  • air = 1.
  • High permittivity of water results from dipole characteristic of water molecules leading to high polarisability.

    High polarisability is lost when water is frozen.

    Water in the rocks

    General mixing law for a multi-component rock system (Birschak et al. 1974) can be applied: ε=∑/n(V_i∗ε_i)
      Vi, ε_i volumetric content and permittivity of each component (rock matrix, pore water, etc.)
      A special case is given by Schön (1996):

  • ε=φS_w ε_water+φ(1-S_w ) ε_air+(1-φ)ε_matrix
  •  
  • ε_matrix - permittivity of rock matrix (e.g. quartz grains);
  • ε_water - permittivity of water;
  • ε_air - permittivity of air;
  • φ – porosity;
  • S_w - saturation degree.
  • How ?

    1. Because of high dielectric permittivity of water the level of water table presented as good reflection surface.

    2. Wave velocity will decrease in aquifer because of:

    V=c/√ε

    GPR is useful for groundwater detection.
    The groundwater can be detected in different geological structures
    because of specific dielectric properties of water rich deposits

    Work examples

    Location of aquifer on GPR profile

    South Africa, 2013

    The water table can be detected very clear.

    Changes in wave pattern can be detected    in aquifer and deeper.

    Aquifer on GPR profile and
    confirmation by drillholes
    Water basins and reservoirs

    The search for underground communications

    Q-factor - The ratio of the central frequency of the signals spectrum to its bandwidth

    Radarogram signals –Amplitudes of signals of  GPR profile

    W-factor - Volumetric water content

    Chile, 2016

    Search groundwater for Agronomy

    South Africa, 2017

    Borehole TR 12-960 was drilled based on results of the GPR traverse 12, the anomaly was interpreted to be a fault/shear zone approximately 200 m wide. The geological map for thesite confirms the shear zone which strikes in a north easterly direction. The borehole was drilled to a final depth of 60 m at a diameter of 8 inches, then further reamed to a 12 inch diameter in order for casing to be installed. During drilling dolomites and limestone was intersected, with a large cavity identified between 40 and 60 m bgl. The main water strike was intersected at 27 m bgl in a fractured zone above the main cavity zone and the preconstruction blow yield was 10 l/s (with air loss). 

    Borehole TR 12-960 (RD) was drilled approximately 10 m north of borehole TR 12-960 as a replacement borehole. The borehole was drilled to a final depth of 60 m at a diameter of 8 inches. The borehole intersected dolomitic sedimentary rock units and limestone, with the main water strike at 25 m bgl within a fractured zone yielding approximately 10 l/s (with air loss). The drillers were unable to construct the borehole due to surface blow out.

    Borehole TR 12-610 was drilled based on a vertical anomaly identified on GPR traverse 12. Based on interpretations of the GPR data and geology maps available for the area the anomaly is most likely to be related to the shear zone targeted by boreholes TR 12-960 and TR 12-960 (RD). During drilling dolomitic siltstone and shale was intersected, as well as limestone at depth. The borehole was drilled to a final depth of 36 m and further reamed to 12 inch diameter up to 30 m. The borehole was constructed using 18 m of slotted and 10 m of solid steel 8 inch diameter casing. The main water strike was within a highly fractured zone at 25 m bgl and the final blow yield was 12.5 l/s.